700
IP Telephone Terminal Basic Data Setup –
Registration Expire Timer for NAT
On a per station basis, this setting defines the
SIP registration expiry timer.
If this value is set to 0, for a NAPT terminal, the
value in Program 84-23-01 is applied.
60 ~ 65535 seconds
0 = Disable
IP Telephone Terminal Basic Data Setup –
Subscribe Expire Timer for NAT
On a per station basis, this setting defines the
SIP Subscribe expiry timer.
If this value is set to 0, for a NAPT terminal, the
value in Program 84-23-02 is applied.
60 ~ 65535 seconds
0 = Disable
IPL Basic Setup – IP Address
Assign the IP address for each DSP on the
GPZ-IPLE.
IPL Basic Setup – RTP Port Number
Assign the RTP port number to be used for
each DSP on the GPZ-IPLE.
Only even numbered ports are supported.
IPL Basic Setup – RTCP Port Number (RTP
Port Number + 1)
Define the TCP port number for RTCP to use
for each DSP.
In addition to the above programming, define the programming options as required for the system