903
Program
Number
Program Name/Description
Input Data
Default
34-05-01
Tie Line Outgoing Call Restriction
Build a restriction matrix for outgoing trunk calls
placed over a Tie Line. For each Tie Line trunk
group, Enable/ Disable outgoing access to each
CO trunk group.
0 = Enable (Y-Tandem)
1 = Disable (N-Tandem)
0
34-06-01
Add/Delete Digit for E&M Tie Line Delete
Digit
Some Tie Line networks pass the location
number and extension number to the remote
side. If the system should ignore these digits,
use this program to define the number of digits
which should be deleted for a call.
0 ~ 255
(255 = delete all digits)
0
34-06-02
Add/Delete Digit for E&M Tie Line
Additional Dial Digits
If a Tie Line network requires additional digits to
reroute the call to a location, enter the digits for
the location which should be added to the
received digits.
Maximum of four digits
(0 ~ 9, *, #)
No Setting
34-07-01
E&M Tie Line Timer First Digit Pause (E&M
Immediate Start)
Define the First Digit Pause (E&M Immediate
Start) timer.
0 ~ 64800 seconds
3
34-07-02
E&M Tie Line Timer First Digit Pause (E&M
Wink Start)
Define the First Digit Pause (E&M Wink Start)
timer.
0 ~ 64800 seconds
0
34-07-03
E&M Tie Line Timer First Digit Pause (LD
Trunk)
Define the First Digit Pause (LD Trunk) timer.
0 ~ 64800 seconds
3
34-07-04
E&M Tie Line Timer LD Trunk Guard Time
Define the LD Trunk Guard Time.
0 ~ 64800 seconds
0
34-07-05
E&M Tie Line Timer Trunk Answer Detect
Timer for E&M
Define the Trunk Answer Detect Timer for E&M
timer.
0 ~ 64800 seconds
30
34-08-01
Toll Restriction Data for E&M Tie Lines
Define the toll restriction data for E&M Tie Lines
if required. This must be defined if toll restriction
is enabled in Program 21-05-13.
Maximum of 10 digits
(0 ~ 9, *, #)
No Setting
80-03-01
DTMF Tone Receiver Setup Detect Level
Use Items 11~32 to set the criteria for dial tone
detection for outgoing ARS calls.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
Type 1 ~ 5 = 0