909
Program
Number
Program Name/Description
Input Data
Default
81-11-10
Tie Line Initial Setup Wink/Delay Signal
Detect Timeout Selection
Specify a maximum time for receiving an
acknowledgment signal from a distant system
before sending a busy tone.
0 = 8
1 ~ 15
(1 ~ 15 seconds)
7
81-11-11
Tie Line Initial Setup Disconnect
Recognition Time Selection
Specify the minimum time before a
disconnected circuit can be accessed again.
1 ~ 15
(0.1 ~ 1.5 seconds)
(0 = No Setting)
3 (0.3 seconds)
81-11-12
Tie Line Initial Setup Automatic Release
Signal Detection Selection
Specify the signal detection time for release of
a Tie Line after a disconnect signal is received
from the distant Central Office or PBX.
1 ~ 14
(50 ~ 700 ms)
15 = (No Limit)
(0 = No Setting)
7 (350ms)
81-11-13
Pause Time Selection
Specify the length of a pause (500 ~ 7500ms).
1 ~ 15 (500 ~ 7500ms
6 (3000ms)