925
Program
Number
Program Name/Description
Input Data
Default
12-02-02
Automatic Night Service End Time
For each Night Service Group (01 ~ 32), enter
up to 20 end times (0000 ~ 2359) for each Time
Pattern (1 ~ 10).
0000 ~ 2359
12-02-03
Automatic Night Service Operation Mode
For each Night Service Group (01 ~ 32), define
the Night Service Mode (1 ~ 8) for up to 20
start/end times for each Time Pattern (1 ~ 10).
1 ~ 8
12-03-01
Weekly Night Service Switching
Assign one of the 10 Time Patterns
programmed in Program 12-02-01 to each day
of the week.
Night Mode Service Group
Numbers: 01 ~ 32
Time Schedule Pattern Number:
1 ~ 10
Day of Week:
01 = Sunday
02 = Monday
03 = Tuesday
04 = Wednesday
05 = Thursday
06 = Friday
07 = Saturday
01 = Sunday
(default = Time
Pattern 2)
02 = Monday
(default = Time
Pattern 1)
03 = Tuesday
(default = Time
Pattern 1)
04 = Wednesday
(default = Time
Pattern 1)
05 = Thursday
(default = Time
Pattern 1)
06 = Friday
(default = Time
Pattern 1)
07 = Saturday
(default = Time
Pattern 2)
12-04-01
Holiday Night Service Switching
Assign one of the 10 Time Patterns to holidays.
Days and Months:
0101 ~ 1231
(e.g. 0101 = Jan. 1; 1231 = Dec.
31)
Time Pattern Number:
0 ~ 10
(0 = No Setting)
No Setting
12-05-01
Night Mode Group Assignment for
Extensions
Assign a Day/Night Mode Group (01 ~ 32), for
each extension.
Night Mode Service Group
Number:
01 ~ 32
1
12-06-01
Night Mode Group Assignment for Trunks
Assign a Day/Night Mode Group (01 ~ 32), for
each trunk port (1 ~ 400).
Trunk Port Number: 001 ~ 400
Night Mode Service Group
Number:
01 ~ 32
1