951
Guide to Feature Programming
General Purpose Relay Setup – Slot No.
Physical Port of DLCA Sensor Circuit No.
Define which relay circuits (5 ~ 8) on the
PGD(2)-U10 ADP are used for General
Purpose Relays.
Slot No: 0 ~ 24
DCLA Port: 0 ~ 16
Relay No: 0, 5 ~ 8
After each entry, press
Transfer to advance to the next
entry.
GCD-CP10 Hardware Setup – External
Source I/O Selection on GCD-CP10
Define how the I/O ports on the GCD-CP10 are
used.
0 = External MOH (AUX2)/
External Speaker(AUX1)
1 = BGM source (AUX2)/
External Speaker(AUX1)
2 = External MOH (AUX2)/
BGM source (AUX1)
Relationships between AUX
number and Relay number are as
follows:
AUX2 = Relay2
AUX1 = Relay1
Service Code Setup (For Service Access) –
General Purpose Relay
Specify the service code used to toggle the
relay open and closed.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
Programmable Function Keys
Assign function keys for External Paging zones
(19 + zone) and External All Call Page (20). If
required, define a function key for a multiline
terminal to use the general purpose relay (51).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
Class of Service Options (Supplementary
Service) – Paging Display
Turn Off or On an extension user ability to
display paging information.
System Options for Internal/External Paging
– Page Announcement Duration
Set the maximum allowable duration for a
Paging announcement.
Internal Paging Group Settings – Internal
Paging Group Name
Assign name to Internal Paging Groups (i.e.,
Page Zones). The system shows the name you
program on the telephone display.
Maximum of 12 characters.