Outbound IP Connection:
Program
Number
Program Name/Description
Input Data
Default
10-03-01
ETU Setup
Set up and confirm the basic configuration data
for each blade. This program represents
different data depending on the blade installed
in the slot.
The assigned data varies
depending on the blade installed
in the slot.
11-15-16
Service Code Setup, Administrative (for
Special Access) Outbound IP Connect for
Programming
Assign the service code for Outbound IP
Connection for Programming. This Service
Code is used to invoke TCP establishment
request from SV9100 to remote PCPro.
No Setting
90-10-01
System Alarm Setup Alarm Type
Indicates the alarm type for Failure of Outbound
IP Connection for PC Programming.
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
Alarm 58:
Failure of
Connection
(Outbound IP
Connection)
Adding
parameter:
01:
Programming
session is
already active
02: Not setting of
IP Address or
Port
03: Caller ID is
not match.
10: Failure of
getting IP
Address.
11: Socket Open
Error 12: Socket
Port Setting
Error.
13: TCP Session
Timeout
90-36-01
Firmware Update Time Setting Firmware
Update Schedule Time
Read Only program.
Year: 0 ~ 99
Month: 0 ~ 12
Day: 00 ~ 31
Hour: 00 ~ 23
Minute: 00 ~ 59
No Setting
90-36-02
Firmware Update Time Setting Update
Mode
Read Only program.
0 = Non Active
1 = Activated
No Setting
90-36-03
Firmware Update Time Setting Update
Report
Read Only program.
Maximum of 256 characters.
No Setting
90-69-01
Outbound IP Connection Setup Port
Number
Define the port number used for Outbound IP
Connection for Programming.
1 ~ 65535
8000