Code Contents Solutions
57 @Remote is not connected at the
date/time reserved for receiving
the package firmware update
from the network.
• Check the @Remote connection.
58 Update cannot be done due to a
reception route problem.
• Check the @Remote connection.
59 HDD is not mounted. • Check the HDD connection.
60 HDD could not be used during the
package firmware update.
• Try again.
• Replace the HDD if the download fails
again.
61 The module ID for the package
firmware update is incorrect.
• Prepare the correct package files.
62 The configuration of the package
firmware update files is incorrect.
• Prepare the correct package files.
63 Reception fails due to the power
off at the reserved date/time of
the remote firmware update from
the network.
• Update is to be done automatically when
the next reception time has elapsed.
64 Reception fails due to the power
off at the reserved date/time of
the package firmware update
from the network.
• Reset the reservation date/time for the
remote update.
65 Reception fails due to the status
error of the machine at the
reserved date/time of the remote
firmware update from the network.
• Update is to be done automatically when
the next reception time has elapsed.
66 Reception failed due to the status
error of the machine at the
reserved date/time of the
package firmware update from
the network.
• Reset the reservation date/time for the
remote update.
5. System Maintenance Reference
604

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP CW2201 and is the answer not in the manual?

Ricoh MP CW2201 Specifications

General IconGeneral
Color PrintingYes
Scan Resolution600 dpi
Standard InterfacesEthernet, USB
Paper SizeA4
Operating SystemsWindows
Power SourceAC 100-240V, 50/60Hz