SC202-67 D Head Tank 7: Ink Level Feeler Error 3
The OCFS could not detect the position of the ink level feeler.
Feeler cannot be detected because it is out of position (loose, broken,
defective, or blocked by an obstruction)
Air release solenoid blocked
Maintenance unit defective
Print head ink tank defective
Air release solenoid defective
SC202-70 D Ink Level Feeler Error 4: All Feelers
All ink level sensor feelers were not detected.
Feeler cannot be detected because it is out of position (loose, broken,
defective, or blocked by an obstruction)
Maintenance unit defective
Print head ink tank defective
Air release solenoid defective
SC203 D Supply Pump Suction Timeout Errors
The supply pump motor reversed to apply negative pressure, but the sensor
failed to detect one or more feelers at the prescribed positions, so pressure
could not be detected as normal. Problem may be cause by
An air leak
Clogged tubing between the supply pump and print head
Failure to purge air from the tank
A broken or defective feeler
Feeler broken, damaged, or blocked
Air release solenoid blocked
Air release solenoid defective
Ink supply pump or tube defective
SC203-00 D Air Leak Error
Interrupted during specifying the cause
SC203-11 D Head Tank 1: Air Leak Error