02 D TPM error
03 D TCSD error
• Incorrect updating for the system firmware
• Incorrect operating of the USB flash
• Defective flash ROM on the controller board
• Replace the controller board.
SC880 D File Format Converter Error (MLB) CTL
A request for access to the file format converter board (MLB) was not answered
within the specified time.
• Board defective
SC881 D Authentication area error CTL
Authentication application error is detected.
Error data in an authentication application reaches the management limit.
• Turn the main power switch off and on.
SC899 D Software performance error CTL
If the processing program shows abnormal performance and the program is
abnormally ended, this SC is issued.
• Controller board defective
• Software defective
• Replace the controller board.
• Turn the main switch off and on.
• Update the firmware on the controller.
SC800: Firmware