Boards for HiPath 3000
P31003-H3550-S403-4-7620, 02/05
3-202 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
boards.fm
Peripheral Boards
Configuring S
0
interfaces
Depending on how the interfaces are applied, use HiPath 3000 Manager E to define the rele-
vant protocols for the trunks to be connected. Please note the additional information contained
in the protocol templates when selecting a suitable S
0
protocol:
● CO = Interfaces to the public CO
● Bus = Interfaces to an internal station
● Master = Interfaces for a master system network
● Slave = Interfaces for a slave system network
● H150/H118 or H300 = Defines the CorNet protocol:
– H150/H118 = Optimized for interconnection with HiPath 3000
This option should also be selected in connection with HiPath ProCenter Office HPCO.
– H300 = Optimized for interconnection with HiPath 4000
● Direct or fixed connection: defines the type of connection for a network and controls the
supply of clock pulses:
– Direct = Communication systems are connected to one another by means of a direct
cable connection. The master system supplies the reference clock pulse for the net-
worked system.
– Fixed connection = Communication systems are connected over lines leased from a
network provider (with clock pulse supply). The master system receives the reference
clock pulse from the network.
A slave system always receives the clock pulse from the master system regardless of
whether the connection is direct or fixed.
Use the S
0
interface S
0
1 for connection to the public telecommunications network. You can
also connect S
0
interfaces S
0
2 to S
0
4 to the ISDN trunk or to ISDN terminals (ISDN telephone,
group 4 fax device, PC, dialing aid) via an S
0
bus.