EasyManuals Logo

Siemens HiPath 3000 Service Manual

Siemens HiPath 3000
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #822 background imageLoading...
Page #822 background image
Workpoint Clients
P31003-H3550-S403-4-7620, 02/05
10-26 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
wclient.fm
optiPoint 500
The volume keys on the optiPoint terminal are used to adjust the volume level of the inter-
nal loudspeaker and any connected external loudspeaker. The volume of the external loud-
speaker can also be adjusted using the external amplifier.
Figure 10-16 Y Cable for optiPoint acoustic adapter
Table 10-1 Floating contacts on the optiPoint acoustic adapter
Pin Assign-
ment
Notes
1Free
2 "Busy" con-
tact
Signals active telephone states:
handset lifted
Loudspeaker activated or headset active
These states can be displayed, for example, on external signaling equip-
ment (LED, relay, etc.) The signaling equipment must have its own power
supply.
The contact can be loaded with up to 5 W at 24 Vac or 60 Vdc.
3
Assignment of the MW4 connection sockets:
Internal resistance: 0 ; 10 µF
Level (for PCM -20 dBm): -4.8 dBm (at volume level 8; 0.775
V = 0 dBm)
Sense lead to GND: int. loudspeaker deactivated; only active
for tone ringing.
Input level -50 dBm: -12 dBm PCM signal
Input resistance: 150 k parallel to 220 nF in series with 36
k
Sense lead to GND: internal microphone deactivated.
Pin Signal
1 sense lead
2NF+
3Free
4GND
Pin Signal
1+5V
2GND
3Free
4 sense lead
microphone
41
Y cable
acoustic adapter
loudspeaker

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals