EasyManuals Logo

Siemens HiPath 3000 Service Manual

Siemens HiPath 3000
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #883 background imageLoading...
Page #883 background image
wclient.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
10-87
Workpoint Clients
optiPoint Accessories
10.7 optiPoint Accessories
The following data is valid for the telephone families optiset E, optiPoint 410, optiPoint 420, op-
tiPoint 500 and for the telephone optiPoint 600 office. Restrictions are indicated in the relevant
places.
10.7.1 External AC Adapters
You may need an external AC adapter if you are using large configurations or if you need to
extend the range.
10.7.1.1 Local Power Supply for optiset E, optiPoint 500 and optiPoint 600 office
You can connect a local power supply to the line cords of a host or client telephone using two
MW6 jacks and the connection cable supplied (see Figure 10-32).
Variants
Local power supply, Euro: AUL:06D1284 (C39280-Z4-C71 = number entered on unit)
Local power supply, UK: AUL:06D1287 (C39280-Z4-C72 = number entered on unit)
Local power supply, 110 V USA: AUL:51A4827 (C39280-Z4-C73 = number entered on
unit)
Data for local power supply AUL:06D1284 (Euro)
Line voltage: 220 (230) Vac
AC line frequency: 47 ... 53 Hz
Output voltage: Max. 50 Vdc, min. 30 Vdc
Output current: Max. 250 mA

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals