2.4 System-Specific Capacity Limits for HiPath 3000, HiPath 5000
The maximum capacity limits are calculated based on the following assumptions:
HiPath 3800: 2 board slots are reserved for trunks.
HiPath 3750, HiPath 3700: 3 board slots are reserved for trunks.
HiPath 3550, HiPath 3500: Two S
0
interfaces on the central board + 1 board slot are re-
served for trunks.
HiPath 3350, HiPath 3300: Two S
0
interfaces on the central board are reserved for trunks.
Traffic capacity: 0.15 Erlang
Capacity limits which deviate from these may be specified for sales purposes.
Table 10-3 contains the maximum system-specific configurations for U
P0/E
workpoint clients
and the corresponding key modules and adapters.
Table 2-7 HiPath 3000/5000 - System-Specific Capacity Limits (Maximum Configuration)
System HiPath
3800
1
HiPath
3750
HiPath
3700
HiPath
3550
HiPath
3500
HiPath
3350
HiPath
3300
HiPath
Com-
Scendo
service
Stations/Workpoint Clients
Total Number of TDM and IP Sta-
tions
2
500 250/500
3
192
4
192
5
96
6
96
7
IP stations (system clients, H.323
clients)
500 250/500
3
192
8
192
8
96
8
9
96
8
10
1000
Total number of TDM stations
2
384 250/384
3
96
11
77
11
12
57
13
41
14
TDM Stations
Analog stations 384 250/384
15
96
2
44
16
36
17
20
18
U
P0/E
stations 384 250/384
3
72
19
48
20
24
21
24
22
Additional stations via adapter
(phone adapter/analog adapt-
er/ISDN adapter)
116 116
3
23
48
11
29
11
24
24
24
24
Cordless stations 250 250 64/32
25 26
32 16 16
Base Stations for HiPath Cordless Of-
fice
64 64 16/7 7 3 3
Lines
Total Number of Lines 250 90/250
3
60 60 16 16
Total number of analog trunks and
network trunks
120 90/120
3
60 60 16 8
Total number of digital trunk B-
channels and digital network line B
channels (S
0
, S
2M
)
180 90/180
3
60 60 16 16
CorNet-IP network trunks 128 90/128
3
60 60 16 16 250
HG 1500 boards 88 331 (2
27
)1 (2
27
)–
Gateway channels to the system 128 128 48 48 16 16

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals