EasyManuals Logo

Siemens HiPath 3000 Service Manual

Siemens HiPath 3000
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #710 background imageLoading...
Page #710 background image
HiPath 5000 Startup and Administration
P31003-H3550-S403-4-7620, 02/05
6-56 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
start_h5.fm
GetAccount
Data record structure
Table 6-8 GetAccount - Data Record Structure
No. Pos. Lengt
h
Description
1 1 - 8 8 Date of call end
Format DD.MM.YY, for example "13.09.00"
2 9 - 16 8 Time of call end
Format hh:mm:ss, for example "14:14:00"
3 17 - 19 3 Trunk number
right-aligned with leading blanks, for example " 1"
4 20 - 22 3 Node ID for HiPath 3000 (matches the configuration in HiPath 3000
Manager E)
right-aligned with leading blanks
5 23 - 28 6 Internal extension number
right-aligned with leading blanks
6 29 - 33 5 Call duration in seconds
7 34 - 41 8 Call duration
Format hh:mm:ss, for example "00:04:34
8 42 - 66 25 For incoming calls: external caller number
For outgoing calls: external call number dialed including the call-
by-call number
left-aligned with succeeding blanks
9 67 - 77 11 Number of tariff units
right-aligned with leading blanks
10 78 1 Call type
1: incoming
2: outgoing (default)
11 79 - 89 11 Account code ACCT
left-aligned with succeeding blanks
12 90 - 100 11 MSN used
13 101 -
105
5Trunk
right-aligned with leading blanks
14 106 -
109
4 LCR Selected Route (corresponds to configuration in HiPath 3000
Manager E)
right-aligned with leading blanks
15 110 1 CR

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals