Boards for HiPath 3000
P31003-H3550-S403-4-7620, 02/05
3-242 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
boards.fm
Peripheral Boards
3.3.25 TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (Not for U.S.)
Introduction
The MSI boards TLA2, TLA4 and TLA8 provide 2, 4 and 8 analog trunks (DP and DTMF dialing
method) for HiPath 3550 and HiPath 3350 (wall housing).
Interfaces
Figure 3-101 TLA2, TLA4 (Not for U.S.) - Interfaces (S30817-Q923-Bxxx, -Axxx)
Table 3-107 TLA2, TLA4 (Not for U.S.) - Contact Assignments
Contact Connector X2 Connector X4
1 a trunk 1 GND for GEE50 FKR, otherwise free
2
b trunk 1 b trunk 1
3
a trunk 2 a trunk 1
4 b trunk 2 b trunk 2
5 a trunk 3
1
1Not for TLA2
a trunk 2
6 b trunk 3
1
b trunk 3
1
7 a trunk 4
1
a trunk 3
1
8 b trunk 4
1
b trunk 4
1
9 a trunk 4
1
10 Call charging module assignment (GMZ)
X1
50
2
TLA2/4
X4
X2
1
10
1
8
1
8
To
CUP/
CUC
T/R ports
MSI 1 - 4
To CO
(CO 3, 4
not for
TLA2)
to GEE
Module
X3 (free)

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals