Starting Up HiPath 3000
P31003-H3550-S403-4-7620, 02/05
5-10 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
start_h3.fm
Starting Up HiPath 3800
5.2.6 Customer-Specific Programming
You can program the system using one of the following tools:
● Assistant T (programming telephone, see Appendix A)
● HiPath 3000 Manager E (PC tool)
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
5.2.7 Performing a System Check
Checking the telephones
● Check the time and date display on each telephone. If a display does not appear, either the
telephone or the link is defective. Replace the terminal or fix the link.
● Perform random terminal tests as described in Section 12.3.1.8 on all telephones.
Checking for proper system booting
● Set up internal and external calls at random to check if the system is functioning properly.
>
Changes to the system (for example key programming) made using HiPath 3000
Manager E during an offline programming session will be lost when the database is
loaded.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.