cordless.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
11-11
HiPath Cordless Office
Multi-SLC and System-Wide Networking
Networked HiPath 3000 systems feature
● max. 64 networked systems
● accessible using a shared station number (roaming among the systems/nodes)
● call interruption when changing between systems/nodes
Handover from current-location to
current-location cordless board
5
(temporary)
32
(1 for each cordless
board)
Figure 11-3 Example of a Cordless Extension Connection in Networked Systems
Table 11-8 Required B channels for Multi-SLC and System-Wide Networking
Mobile telephone (MT) has set
up a connection
Required B
channels
Required B chan-
nels for the home
cordless board
Required B chan-
nels for the cur-
rent-location
cordless board
BS
SLC16
BS
CorNet NQ
Home SLC16
SLC16 no. = 1
Station no. =
124
Current-location
SLC16
SLC16 no. = 11
Station no. = 128
HiPath 3750
Node ID = 1
HiPath 3550
Node ID = 2
Extension
connection
BS
SLC16
BS
SLC16 no. = 2
Station no. =
141
BS
SLC16
BS
BS = BS2/2, BS3/1 or
BS3/3
A CorNet NQ connection is possible using S
0
or S
2M
lines or IP networking (see HG 1500 Administration
Manual).