Service
P31003-H3550-S403-4-7620, 02/05
12-56 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
service.fm
Guided Maintenance
35 No ELIC interrupts Hard restart Notify appropriate service
support
36 SDRAM: Access to protected area Hard restart
37 SDRAM: Write error, wrong address Hard restart
38 SDRAM: Read error, wrong address
Error Class B-30 - Firmware/Loadware
6 HDLC Controller Error on board Reload board Replace board
Error Class B-40 - MMC
0 MMC defective Hard restart Replace MMC
Error Class B-41 - LAN
4 Send: Ethernet driver not ready For errors that appear
sporadically, no action is
necessary.
For errors that appear reg-
ularly, replace the LIM
module. If this does not
correct the error, check
the LAN configuration.
8 Send: More than 15 futile attempts
9 Send: Delayed collision detection
10 Send: Carrier loss
11 Receive: Frame error
12 Receive: FIFO error
13 Receive: Checksum error
14 Receive: Defective receiving buffer
15 Receive: Frame too short
16 Receive: Frame too long
17 Receive: Delayed collision detection
18 Receive: Partial deletion of data due to the
existing write protection
Table 12-7 HiPath 3000 Class B Error Messages
No. Meaning Action