Service
P31003-H3550-S403-4-7620, 02/05
12-56 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
service.fm
Guided Maintenance
35 No ELIC interrupts Hard restart Notify appropriate service
support
36 SDRAM: Access to protected area Hard restart
37 SDRAM: Write error, wrong address Hard restart
38 SDRAM: Read error, wrong address –
Error Class B-30 - Firmware/Loadware
6 HDLC Controller Error on board Reload board Replace board
Error Class B-40 - MMC
0 MMC defective Hard restart Replace MMC
Error Class B-41 - LAN
4 Send: Ethernet driver not ready – For errors that appear
sporadically, no action is
necessary.
For errors that appear reg-
ularly, replace the LIM
module. If this does not
correct the error, check
the LAN configuration.
8 Send: More than 15 futile attempts –
9 Send: Delayed collision detection –
10 Send: Carrier loss –
11 Receive: Frame error –
12 Receive: FIFO error –
13 Receive: Checksum error –
14 Receive: Defective receiving buffer –
15 Receive: Frame too short –
16 Receive: Frame too long –
17 Receive: Delayed collision detection –
18 Receive: Partial deletion of data due to the
existing write protection
–
Table 12-7 HiPath 3000 Class B Error Messages
No. Meaning Action
Recovery
Action
Technician

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals