8. Remove the 6 screws on the FPI board (TX-20).
7;
7;
7;
1P
7;
7;7;
9. Remove the FPI board.
The FPI board is removed.
Installing the FPI board
1. Align the FPI board to the screw holes.
2. Insert 6 screws (TX-20)
3. Plug the IPD.
4. Close the locking devices of the IPD.
5. Plug the connectors onto the FPI board.
6. Mount the front cover.
7. Tighten 2 screws (TX-25) of the front cover.
8. Mount the terminal covers.
9. Tighten the screws (TX-25) of the upper and lower terminal cover.
The FPI board is installed.
Corrective maintenance
10.2 Replacing spare parts
SINAMICS G120X converter
1068 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC