EasyManua.ls Logo

Siemens SINAMICS G120X - Data Type; Scaling; Unit Group and Unit Selection

Siemens SINAMICS G120X
1148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter name
The following abbreviations can appear in front of the names:
BI Binector input
BO Binector output
CI Connector input
CO Connector output
CO/BO Connector/binector output
Interconnecting signals in the converter (Page 464)
Can be changed
"-" The parameter can be changed in any state, and the change becomes imme‐
diately effective.
C(x) The parameter can only be changed for the following settings:
C: p0010 > 0
C(x): p0010 = x
U The motor is switched on
T The motor is switched off and p0010 = 0
Unit group and unit selection
For parameters where the unit can be switched over.
"Unit group": to which group does the parameter belong?
"Unit selection": with which parameter do you switch over the unit?
Data type
Integer8 I8 8-bit integer
Integer16 I16 16-bit integer
Integer32 I32 32-bit integer
Unsigned8 U8 8-bit without sign
Unsigned16 U16 16-bit without sign
Unsigned32 U32 32-bit without sign
FloatingPoint32 Float 32-bit floating-point number
Scaling
Specification of the reference variable with which a signal value is automatically converted with
a BICO interconnection.
The following reference variables are available:
p2000 … p2003: Reference speed, reference voltage, etc.
PERCENT: 1.0 = 100%
4000H: 4000 hex = 100 % (word) or 4000 0000 hex = 100 % (double word)
Parameters
7.1 Explanation of the detailed parameter list
SINAMICS G120X converter
468 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC

Table of Contents

Other manuals for Siemens SINAMICS G120X

Related product manuals