p1523[0...n] CI: Torque limit lower / M_max lower
Access level: 3 Calculated: - Data type: Unsigned32 /
FloatingPoint32
Can be changed: T Scaling: p2003 Dynamic index: CDS, p0170
Unit group: - Unit selection: - Function diagram: 6020, 6630
Min:
-
Max:
-
Factory setting:
1521[0]
Description: Sets the signal source for the lower torque limit.
Dependency: See also: p1520, p1521, p1522
DANGER
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
p1524[0...n] CO: Torque limit upper/motoring scaling / M_max up/mot scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: 5620, 5630
Min:
-2000.0 [%]
Max:
2000.0 [%]
Factory setting:
100.0 [%]
Description: Sets the scaling for the upper torque limit or the torque limit when motoring.
Dependency: p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: PERCENT Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: 6630
Min:
-2000.0 [%]
Max:
2000.0 [%]
Factory setting:
100.0 [%]
Description: Sets the scaling for the lower torque limit.
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
r1526 CO: Torque limit upper without offset / M_max up w/o offs
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dynamic index: -
Unit group: 7_1 Unit selection: p0505 Function diagram: 6060, 6630,
6640
Min:
- [Nm]
Max:
- [Nm]
Factory setting:
- [Nm]
Parameters
7.2 Parameter list
SINAMICS G120X converter
686 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC