≥ 30 ms In case of deviating feedback, the safety relay must select the STO function
and indicate an error.
T
2
≥ 20 ms
Figure 4-30 Dynamic monitoring of STO feedback for FSA … FSG
9'&
6WDUW
0
6,5,866.
/RJLF
)4)4
40
7 ,1,1,1 ,1 ,17,1,1,1,1,1
$
$
;
672B$
672B%
)%B$
)%B%
Figure 4-31 Connection 3SK2 inside a control cabinet for FSH and FSJ
Static monitoring of STO feedback at start-up is sufficient for the converters FSH and FSJ.
Modular 3RK3 safety system
You can use the following outputs to control the failsafe digital inputs in the converter:
● The failsafe digital outputs in the central units of the 3RK3 modular safety system
● The failsafe digital outputs in the EM 2/4F-DI 2F-DO expansion module
● The failsafe digital outputs in the EM 4F-DO expansion module.
● The failsafe relay outputs in the EM 4/8F-RO expansion module
● 2 individual relay contacts of the EM 2/4F-DI 1/2F-RO expansion module
Wiring
4.2 Control interfaces
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 135