Value in p0300 Ethernet/IP motor data object,
0
1
2
10
13
17
19
100
104
107
108
200
204
237
10000
10001
No motor
induction motor
synchronous motor
1LE1 induction motor
1LG6 induction motor
1LA7 induction motor
1LA9 induction motor
1LE1 induction motor
1PH4 induction motor
1PH7 induction motor
1PH8 induction motor
1PH8 synchronous motor
1LE4 synchronous motor
1FK7 synchronous motor
motor with DRIVE-CLiQ
motor with DRIVE-CLiQ 2. D
0
7
3
7
7
7
7
7
3
0
5
0
3
0
0
0
Non-standard motor
squirrel cage induction motor
PM synchronous motor
squirrel cage induction motor
squirrel cage induction motor
squirrel cage induction motor
squirrel cage induction motor
squirrel cage induction motor
PM synchronous motor
non-standard motor
switched reluctance motor
non-standard motor
PM synchronous motor
non-standard motor
non-standard motor
non-standard motor
Supervisor Object, Instance Number: 29 hex
Supported services
Class ● Get Attribute single Instance ● Get Attribute single
● Set Attribute single
Table 6-28 Class Attribute
No
.
Serv‐
ice
Type Name
1 get UINT16 Revision
2 get UINT16 Max Instance
3 get UINT16 Num of Instances
Table 6-29 Instance Attribute
No
.
Serv‐
ice
Type Name Value/explanation
3 get, set Bool Run1 STW.0 operation, clockwise rotation
5 get, set Bool Net Control Internal
0: Local
1: Network
6 get UINT8 State 0: Vendor Specific
1: Startup
2: Not_Ready
3: Ready
4: Enabled
5: Stopping
6: Fault_Stop
7: Faulted
Advanced commissioning
6.3 Drive control
SINAMICS G120X converter