r1198.0...15 CO/BO: Control word setpoint channel / STW setpoint chan
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2505
Min:
-
Max:
-
Factory setting:
-
Description: Display and BICO output for the control word of the setpoint channel.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fixed setpoint bit 0 Yes No 3010
01 Fixed setpoint bit 1 Yes No 3010
02 Fixed setpoint bit 2 Yes No 3010
03 Fixed setpoint bit 3 Yes No 3010
05 Inhibit negative direction Yes No 3040
06 Inhibit positive direction Yes No 3040
11 Setpoint inversion Yes No 3040
13 Motorized potentiometer raise Yes No 3020
14 Motorized potentiometer lower Yes No 3020
15 Bypass ramp-function generator Yes No 3070
r1199.0...8 CO/BO: Ramp-function generator status word / RFG ZSW
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 3001, 3080
Min:
-
Max:
-
Factory setting:
-
Description: Displays the status word for the ramp-function generator (RFG).
Bit field: Bit Signal name 1 signal 0 signal FP
00 Ramp-up active Yes No -
01 Ramp-down active Yes No -
02 RFG active Yes No -
03 Ramp-function generator set Yes No -
04 Ramp-function generator held Yes No -
05 Ramp-function generator tracking active Yes No -
06 Maximum limit active Yes No -
07 Ramp-function generator acceleration positive Yes No -
08 Ramp-function generator acceleration negative Yes No -
Note
For bit 02:
The bit is the result of the OR logic operation - bit 00 and bit 01.
p1200[0...n] Flying restart operating mode / FlyRest op_mode
Access level: 2 Calculated: - Data type: Integer16
Can be changed: T, U Scaling: - Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: 6300, 6850
Min:
0
Max:
4
Factory setting:
0
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 643