r1926[0...2] Identified effective valve lockout time / t_lock_valve id
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
- [µs]
Max:
- [µs]
Factory setting:
- [µs]
Description: Displays the identified effective valve lockout time.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
r1927[0...2] Identified rotor resistance / R_rotor ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
- [ohm]
Max:
- [ohm]
Factory setting:
- [ohm]
Description: Displays identified rotor resistance (on separately excited synchronous motors: damping resistance).
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
p1959[0...n] Rotating measurement configuration / Rot meas config
Access level: 3 Calculated: CALC_MOD_ALL Data type: Unsigned16
Can be changed: T Scaling: - Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
0000 0000 0001 1110 bin
Description: Sets the configuration of the rotating measurement.
Bit field: Bit Signal name 1 signal 0 signal FP
01 Saturation characteristic identification Yes No -
02 Moment of inertia identification Yes No -
03 Re-calculates the speed controller parameters Yes No -
04 Speed controller optimization (vibration test) Yes No -
11 Do not change the controller parameters during the
measurement
Yes No -
12 Measurement shortened Yes No -
13 After measurement direct transition into operation Yes No -
14 Calculate speed actual value smoothing time Yes No -
Dependency: See also: F07988
Note
The following parameters are influenced for the individual optimization steps:
Bit 01: p0320, p0360, p0362 ... p0369
Bit 02: p0341, p0342
Bit 03: p1400.0, p1458, p1459, p1463, p1470, p1472, p1496
Bit 04: Dependent on p1960
p1960 = 1, 3: p1400.0, p1458, p1459, p1470, p1472, p1496