r29549 CO/BO: Multi-pump control feedback signal for contactor / Mpc fdb signal
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Bico to p1269[0] as a feedback signal
p29570[0...n] Ramp-up scaling 1 / RmpUpScaling1
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: -
Min:
0.00 [%]
Max:
9999999.00 [%]
Factory setting:
100.00 [%]
Description: Sets the ramp-up scaling 1 for the dual ramp function [%].
Note
The linear acceleration time from speed 0 to speed p29571 can be calculated via formula
(p29571/p1082)*p1120*p29570.
If p1130 is not equal to 0, the time will be adapted.
p29571[0...n] Threshold speed 2 / Thresh_2_Ramp
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: p2000 Dynamic index: DDS, p0180
Unit group: 3_1 Unit selection: p0505 Function diagram: -
Min:
0.00 [rpm]
Max:
210000.00 [rpm]
Factory setting:
30.00 [rpm]
Description: Defines the threshold 2 for comparing the speed actual value with the speed threshold.
p29572[0...n] Ramp-up scaling 2 / RmpUpScaling2
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: -
Min:
0.00 [%]
Max:
9999999.00 [%]
Factory setting:
100.00 [%]
Description: Sets the ramp-up scaling 2 for the dual ramp function [%].
Note
The linear acceleration time from speed p29571 to constant speed V can be calculated via formula
((V-p29571)/p1082)*p1120*p29572.
If p1130 is not equal to 0, the time will be adapted.
p29573[0...n] Ramp-down scaling 1 / RmpDnScaling1
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dynamic index: DDS, p0180
Unit group: - Unit selection: - Function diagram: -
Min:
0.00 [%]
Max:
9999999.00 [%]
Factory setting:
100.00 [%]
Description: Defines the ramp-down scaling 1 for the dual ramp function [%].