p2051[0...16] CI: PROFIdrive PZD send word / PZD send word
G120X_DP,
G120X_PN
Access level: 3 Calculated: - Data type: Unsigned32 /
Integer16
Can be changed: T, U Scaling: 4000H Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2450, 2470,
9370
Min:
-
Max:
-
Factory setting:
[0] 2089[0]
[1] 63[0]
[2...16] 0
Description: Selects the PZD (actual values) with word format to be sent to the fieldbus controller.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
NOTICE
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2051[0...16] CI: PROFIdrive PZD send word / PZD send word
G120X_USS Access level: 3 Calculated: - Data type: Unsigned32 /
Integer16
Can be changed: T, U Scaling: 4000H Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2450, 2470,
9370
Min:
-
Max:
-
Factory setting:
0
Description: Selects the PZD (actual values) with word format to be sent to the fieldbus controller.
Parameters
7.2 Parameter list
SINAMICS G120X converter
746 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC