p1023 p1022 p1021 p1020 Resulting setpoint
0 1 1 1 p1001 + p1002 + p1003
1 0 0 0 p1004
1 0 0 1 p1001 + p1004
1 0 1 0 p1002 + p1004
1 0 1 1 p1001 + p1002 + p1004
1 1 0 0 p1003 + p1004
1 1 0 1 p1001 + p1003 + p1004
1 1 1 0 p1002 + p1003 + p1004
1 1 1 1 p1001 + p1002 + p1003 + p1004
Selecting the fixed speed setpoint, binary
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQWHIIHFWLYH
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
U
S
S
S
S
S
S
S
S
S
Figure 6-46 Binary selection of the fixed speed setpoint
Table 6-81 Resulting setpoint
p1023 p1022 p1021 p1020 Resulting setpoint
0 0 0 0 0
0 0 0 1 p1001
0 0 1 0 p1002
0 0 1 1 p1003
0 1 0 0 p1004
0 1 0 1 p1005
0 1 1 0 p1006
0 1 1 1 p1007
1 0 0 0 p1008
1 0 0 1 p1009
1 0 1 0 p1010
1 0 1 1 p1011
1 1 0 0 p1012
1 1 0 1 p1013
1 1 1 0 p1014
1 1 1 1 p1015
Advanced commissioning
6.5 Setpoints and setpoint processing
SINAMICS G120X converter
334 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC