Selecting the number of drive data sets
Parameter p0180 defines the number of drive data sets (1 ... 4).
Parameter Description
p0010 = 0 Drive commissioning: Ready
p0010 = 15 Drive commissioning: Data sets
p0180 Drive data set (DDS) number
Copying the drive data sets
Parameter Description
p0819[0] Source drive data set
p0819[1] Target drive data set
p0819[2] = 1 Starts the copy operation
Parameters
Number Name Factory setting
p0010 Drive commissioning parameter filter 1
r0051 CO/BO: Drive data set DDS effective -
p0180 Drive data set (DDS) number 1
p0819[0 … 2] Copy drive data set DDS 0
p0820[C] BI: Drive data set DDS selection, bit 0 0
p0821[C] BI: Drive data set DDS selection, bit 1 0
p0826[M] Motor changeover, motor number 0
More information
The converter switches the motor data set (MDS) and the power unit data set (PDS) together
with the drive data set (DDS).
Advanced commissioning
6.11 Switchover between different settings
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 461