p9930[0...8] System logbook activation / SYSLOG activation
Access level: 4 Calculated: - Data type: Unsigned8
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
0
Max:
255
Factory setting:
0
Description: Only for service purposes.
Index: [0] = System logbook stage (0: Not active)
[1] = COM2/COM1 (0: COM2, 1: COM1)
[2] = Activate file write (0: Not active)
[3] = Display time stamp (0: Not displayed)
[4...7] = Reserved
[8] = System logbook file size (stages, each 10 kB)
NOTICE
Before switching off the Control Unit, ensure that the system logbook is switched out (p9930[0] = 0).
If writing to the file is activated (p9930[2] = 1), writing to the file must be deactivated again before switching off the
Control Unit (p9930[2] = 0) in order to ensure that the system logbook has been completely written to the file.
p9931[0...180] System logbook module selection / SYSLOG mod select.
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
0000 hex
Max:
FFFF FFFF hex
Factory setting:
0000 hex
Description: Only for service purposes.
p9932 Save system logbook EEPROM / SYSLOG EEPROM save
Access level: 4 Calculated: - Data type: Unsigned8
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
0
Max:
255
Factory setting:
0
Description: Only for service purposes.
r9935.0 BO: POWER ON delay signal / POWER ON t_delay
Access level: 4 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Display and binector output for a delay after POWER ON.
After switch-on, binector output r9935.0 is set with the start of the first sampling time and is again reset after approx.
100 ms.
Bit field: Bit Signal name 1 signal 0 signal FP
00 POWER ON delay signal High Low -
Parameters
7.2 Parameter list
SINAMICS G120X converter
892 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC