r1084 CO: Speed limit positive effective / n_limit pos eff
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dynamic index: -
Unit group: 3_1 Unit selection: p0505 Function diagram: 3050, 7958
Min:
- [rpm]
Max:
- [rpm]
Factory setting:
- [rpm]
Description: Display and connector output for the active positive speed limit.
Dependency: See also: p1082, p1083, p1085
Note
Vector control: r1084 <= 60 x 240 Hz / r0313
p1085[0...n] CI: Speed limit in positive direction of rotation / n_limit pos
Access level: 3 Calculated: - Data type: Unsigned32 /
FloatingPoint32
Can be changed: T Scaling: p2000 Dynamic index: CDS, p0170
Unit group: - Unit selection: - Function diagram: 3050
Min:
-
Max:
-
Factory setting:
1083[0]
Description: Sets the signal source for the speed limit of the positive direction.
p1086[0...n] CO: Speed limit in negative direction of rotation / n_limit neg
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T, U Scaling: p2000 Dynamic index: DDS, p0180
Unit group: 3_1 Unit selection: p0505 Function diagram: 3050
Min:
-210000.000 [rpm]
Max:
0.000 [rpm]
Factory setting:
-210000.000 [rpm]
Description: Sets the speed limit for the negative direction.
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
r1087 CO: Speed limit negative effective / n_limit neg eff
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dynamic index: -
Unit group: 3_1 Unit selection: p0505 Function diagram: 3050, 7958
Min:
- [rpm]
Max:
- [rpm]
Factory setting:
- [rpm]
Description: Display and connector output for the active negative speed limit.
Dependency: See also: p1082, p1086, p1088
Note
Vector control: r1087 >= -60 x 240 Hz / r0313
p1088[0...n] CI: Speed limit in negative direction of rotation / n_limit neg
Access level: 3 Calculated: - Data type: Unsigned32 /
FloatingPoint32
Can be changed: T Scaling: p2000 Dynamic index: CDS, p0170
Unit group: - Unit selection: - Function diagram: 3050
Min:
-
Max:
-
Factory setting:
1086[0]