p8809[0...53] Identification and Maintenance 4 / I&M 4
G120X_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
0000 bin
Max:
1111 1111 bin
Factory setting:
0000 bin
Description: Parameters for the PROFINET data set "Identification and Maintenance 4" (I&M 4).
This information is known as "Signature".
Dependency: This parameter is preassigned as standard (see note).
After writing information to p8809, p8805 is automatically set to = 1.
See also: p8805
Note
For p8805 = 0 (factory setting) the following applies:
Parameter p8809 contains the information described below.
For p8809[0...3]:
Contains the value from r9781[0] "SI change tracking checksum functional".
For p8809[4...7]:
Contains the value from r9782[0] "SI change tracking time stamp checksum functional".
For p8809[8...53]:
Reserved.
r8854 PROFINET state / PN state
G120X_PN Access level: 4 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
0
Max:
255
Factory setting:
-
Description: State display for PROFINET.
Value: 0: No initialization
1: Fatal fault
2: Initialization
3: Send configuration
4: Receive configuration
5: Non-cyclic communication
6: Cyclic communications but no setpoints (stop/no clock cycle)
255: Cyclic communication
r8858[0...39] PROFINET read diagnostics channel / PN diag_chan read
G120X_PN Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Displays the PROFINET diagnostics data.
Note
Only for internal Siemens diagnostics.
Parameters
7.2 Parameter list
SINAMICS G120X converter
880 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC