p8552 IOP speed unit / IOP speed unit
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
1
Max:
2
Factory setting:
1
Description: Sets the unit for displaying and entering speeds.
Value: 1: Hz
2: rpm
p8558 BI: Select IOP manual mode / Sel IOP man mode
Access level: 3 Calculated: - Data type: Unsigned32 / Binary
Can be changed: T, U Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
0
r8570[0...39] Macro drive object / Macro DO
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency: See also: p0015
Note
For a value = 9999999, the following applies: The read operation is still running.
r8571[0...39] Macro Binector Input (BI) / Macro BI
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note
For a value = 9999999, the following applies: The read operation is still running.
r8572[0...39] Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description: Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency: See also: p1000
Note
For a value = 9999999, the following applies: The read operation is still running.
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 877