Procedure for converters in frame sizes FSA ... FSC
&RQQHFWLRQ$IRUVHOHFWLRQRI672
&RQQHFWLRQ%IRUVHOHFWLRQRI672
6ZLWFKHVWRHQDEOHRUGLVDEOH672
Both switches = ON: STO is enabled
Both switches = OFF: STO is locked
Two switches different: not permissible
Figure 4-23 Terminals and switches for the "STO" function, frame sizes FSA ... FSC
1. Connect the cables for selecting STO to terminals STO_A and STO_B.
2. Connect the cables for STO feedback to 2 digital outputs of terminal block X134.
;
3. Attach the shield to the shield plate of the converter through the largest possible surface
area.
You have connected all cables for the STO safety function.
Wiring
4.2 Control interfaces
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 129