Note
Parameter p60000 is an image of parameter p2000 in conformance with PROFIdrive. A change always effects both
parameters.
If a BICO interconnection is established between different physical quantities, then the particular reference quantities
are used as internal conversion factor.
Example:
The setpoint from PROFIBUS (r2050[1]) is connected to a speed setpoint (e.g. p1070[0]). The actual input value is
cyclically converted into a percentage value via the pre-specified scaling 4000 hex. This percentage value is converted
to the absolute speed setpoint using the reference speed (p60000).
The setpoint from PROFIBUS (r2060[1]) is connected to a speed setpoint (e.g. p1155[0]). The actual input value is
cyclically converted into a percentage value via the pre-specified scaling 4000 0000 hex. This percentage value is
converted to the absolute speed setpoint using the reference speed (p60000).
r61000[0...239] PROFINET Name of Station / PN Name of Station
G120X_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2410
Min:
-
Max:
-
Factory setting:
-
Description: Displays PROFINET Name of Station.
NOTICE
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
r61001[0...3] PROFINET IP of Station / PN IP of Station
G120X_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dynamic index: -
Unit group: - Unit selection: - Function diagram: 2410
Min:
-
Max:
-
Factory setting:
-
Description: Displays PROFINET IP of Station.
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 935