Number Name Factory setting
p2080[0…15] BI: Binector-connector converter, status word 1 [0] 899
[1] 899.1
[2] 899.2
[3] 2139.3
[4] 899.4
[5] 899.5
[6] 899.6
[7] 2139.7
[8] 2197.7
[9] 899.9
[10] 2199.1
[11] 1407.7
[12] 0
[13] 2135.14
[14] 2197.3
[15] 2135.15
r2090.0…15 BO: PROFIdrive receive PZD1 bit by bit -
r2091.0…15 BO: PROFIdrive PZD2 receive bit-serial -
r2092.0…15 BO: PROFIdrive PZD3 receive bit-serial -
r2093.0…15 BO: PROFIdrive PZD4 receive bit-serial -
6.3.3.6 Acyclically reading and writing converter parameters
Overview
The converter supports the writing and reading of parameters via acyclic communication.
6.3.3.7 Reading and changing parameters via data set 47
Note
Values in italics
Values in italics in the following tables mean that you have to adjust these values for a specific
request.
Reading parameter values
Table 6-13 Request to read parameters
Data block Byte n Bytes n + 1 n
Header Reference
01 hex ... FF hex
01 hex: Read job 0
01 hex (ID of drive objects, at G120 always = 1) Number of parameters (m) 2
Advanced commissioning
6.3 Drive control
SINAMICS G120X converter
220 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC