Property Explanation
Surrounding air temperature dur‐
ing storage
FSA ... FSG: -40 °C to +70 °C
FSH/FSJ: -25 °C to +55 °C
-40 °C for maximal 24 h
Shock and vibration
FSA ... FSG
Transport in transportation packaging according to Class 2M3 according to EN
61800-5-1 and EN 60068-2-6
Vibration in operation according to Class 3M1 according to EN 60721-3-3: 1995
FSH/FSJ
Vibration during operation: Fc test according to EN 60068-2-6 0.075 mm for 10 ...
58 Hz 9.81 m/s² (1 x g) at > 58 ... 200 Hz
Shock during operation: Test according to EN 60068- 2-27 (EA shock type) 49 m/
s² (5 x g)/30 ms 147 m/s² (15 x g)/11 ms
Vibration during product packaging: Fc test according to EN 60068-2-6 ±1.5 mm for
5 ... 9 Hz 0.5 g at 9 ... 200 Hz
Shock during product packaging: Fc test according to EN 60068-2-6 ±1.5 mm for
5 ... 9 Hz 0.5 g at 9 ... 200 Hz
Protection against chemical sub‐
stances
Protected according to EN 60721‑3‑3:
FSA ... FSG
Class 3C2
Class 3C3 (available for converters with PROFINET fieldbus only)
3)
FSH/FSJ: Class 3C2
Pollution Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Sound pressure level LPA (1 m) ≤ 74 dB (A)
4)
Cooling method Air forced cooling
Cooling air Clean and dry air
1)
Overvoltage category: III is only supported on the G120X converter with FS version 02 02 (FSA ... FSG)/02 (FSH/FSJ) or
higher.
2)
The data is valid without BOP-2, IOP-2 or SINAMICS G120 Smart Access.
3)
Converters with BOP-2 or IOP-2 installed are not designed for operation under the condition of environment class 3C3. But
SIPLUS IOP-2 with environment class 3C4 (article number: 6AG1255-0AA00-2JA2) can be ordered as an optional
component to meet the requirement.
4)
Maximum sound pressure level, ascertained in the IP20 cabinet.
Technical data
11.3 General converter technical data
SINAMICS G120X converter
1088 Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC