The converter evaluates its control commands depending on digital input DI 3:
● Via a fieldbus from a central control system
● Via the converter digital inputs at the installation.
Note
The converter requires approx. 4 ms to switch over the command data set.
Parameters
Number Name Factory setting
p0010 Drive commissioning parameter filter 1
r0050 CO/BO: Command data set CDS effective -
p0170 Number of command data sets (CDS) 2
p0809[0 … 2] Copy command data set CDS 0
p0810 BI: Command data set selection CDS bit 0 Dependent on the
converter
p0811 BI: Command data set selection CDS bit 1 0
Advanced commissioning
6.3 Drive control
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC 293