5. PARAMETERS
5 - 42
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT
EIP
PNT
PB51
NHQ5
Notch shape
selection 5
Set forms of the machine resonance suppression filter 5.
When "Robust filter selection" is set to "Enabled (_ _ _ 1)" in [Pr. PE41], the machine resonance suppression filter 5
is not available.
_ _ _ x
Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _
Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
0h
x _ _ _
For manufacturer setting
0h
PB52
VRF21
Vibration
suppression
control 2 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If
a value out of the range is set, the vibration suppression control will be disabled.
Refer to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB53
VRF22
Vibration
suppression
control 2 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If
a value out of the range is set, the vibration suppression control will be disabled.
Refer to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB54
VRF23
Vibration
suppression
control 2 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
Refer to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
PB55
VRF24
Vibration
suppression
control 2 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
Refer to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30