PT21
*LNPL
Position
range output
address -
(lower four
digits)
Set an address decreasing side of the position range output address.
Upper and lower are a set. Set a range which S_POT (Position range) turns on with
[Pr. PT19] to [Pr. PT22].
Setting address:
[Pr. PT21]
[Pr. PT22]
Upper four
digits
Lower four
digits
This function will be enabled in the point table method.
The unit can be changed to 10
STM
[μm], 10
(STM-4)
[inch], 10
-3
[degree] or [pulse] with
the setting of [Pr. PT01].
Setting range: 00000000h to FFFFFFFFh
0000h
Refer
to
Function
column
for unit.
PT22
*LNPH
Position
range output
address -
(upper four
digits)
0000h
Refer
to
Function
column
for unit.
PT26
*TOP2
Function
selection T-2
Electronic gear fraction clear selection
0: Disabled
1: Enabled
Selecting "Enabled" will clear a fraction of the previous command by the electronic
gear at start of the profile position mode (pp) and the point table mode (pt).
This function will be enabled in the profile mode.
PT27
*ODM
Indexer
method -
Operation
mode
selection
Jog mode method selection
0: Station JOG operation
1: JOG operation
This function will be enabled in the indexer method.
PT28
*STN
Number of
stations per
rotation
Set the number of stations per rotation (number of indexer stations).
Setting "2" or less will be "2".
This function will be enabled in the indexer method.
Setting range: 0 to 255