18 - 61
18EtherCAT COMMUNICATION
(5) CiA 402-type homing method
(a) Home position return type in CiA 402 type
The following shows the CiA 402-type home position return.
1) Method 3 and 4: Homing on positive home switch and index pulse
These home position return types use the front end of the proximity dog as reference and set the
Z-phase right before and right after the dog as a home position.
Method 3 has the operation of the dog type last Z-phase reference home position return, and
Method 4 has the operation of the dog cradle type home position return at a forward rotation start.
However, if the stroke end is detected during home position return, [AL. 90] occurs.
3
3
4
4
Index Pulse
Home Switch
2) Method 5 and 6: Homing on negative home switch and index pulse
These home position return types use the front end of the proximity dog as reference and set the
Z-phase right before and right after the dog as a home position. Method 5 and 6 differ from
Method 3 and Method 4 in the starting direction: the starting direction of Method 5 and 6 is the
reversed direction.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals