Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-151
FIP 1. 63
016-786 Data Send/Receive Timeout Error
Cause:
Timeout error occurs in scan data send/receive.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Check if the network cable is disconnected or connected properly. When there is no problem
with network cable, contact Server Administrator.
2. Perform the following in sequence.
• " Network System Fault Check"
• " Network-related Details Check Flow"
3. Take corrective actions at the host side.
FIP 1. 64
016-790 F2N Module Starting-up
Cause:
F2N module task is starting up, or IP address is not determined.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Check if the network cable is disconnected or connected properly. When there is no problem
with network cable, contact Server Administrator.
2. Take corrective actions at the host side.