Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-211
FIP 1. 184
033-524 JBF_ERROR_MARKER_BAD_ATMOVE
Cause:
Adaptive template is moved incorrectly.
Solution:
The machine will recover after the OK or Close button is pressed or message is displayed for
specified time.
If the error persists:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.1 ESS PWB).
FIP 1. 185
033-525 JBF_ERROR_MARKER_BAD_NEWLEN
Cause:
Image height is changed incorrectly.
Solution:
The machine will recover after the OK or Close button is pressed or message is displayed for
specified time.
If the error persists:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.1 ESS PWB).