Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-295
FIP 1. 334
117-365 Low Voltage
Cause:
RTC detected Low Voltage. RTC clock setting and content of SRAM are invalid. Initialize them.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.1 ESS PWB).
FIP 1. 335
117-367 FXIF error
Cause:
An error occurred on FXIF (such as the Video Underrun error).
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Then update to the latest F/W.
3. If the problem cannot be solved, replace the following parts in sequence.
•(REP 5.1 ESS PWB)
(REP 6.1 IIT Assembly)