Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-287
FIP 1. 314
116-364 Timer Fail
Cause:
Timer error is detected.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, set the RTC correctly.
FIP 1. 315
116-366 PCI Bus #1 Error Detected>
Cause:
PCI Bus #1 Uncorrectable Error Detected.
(Connected with RemoraEX(x1 port))
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.1 ESS PWB).
FIP 1. 316
116-368 PCI Error Messages received from Bus #0 - Device #1
Cause:
Remora EX PCI x1 port Error. (Device ID 0x65 (x1))
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace (REP 5.1 ESS PWB).