Address Name / seng range / [default seng] Info
0x2637:011
(P431.11)
Analog input 2: Min torque value
(Analog input 2: Min. torque)
-400.0 ... [0.0] ... 400.0 %
From version 03.00
Denion of the seng range for operang mode "MS: Torque mode".
100 % ≡ permissible maximum torque 0x6072 (P326.00)
Direcon of rotaon according to sign.
The standard setpoint source for operang mode 0x6060 (P301.00) =
"MS: Torque mode [-1]" is selected in 0x2860:003 (P201.03).
4Conguring the torque control ^ 149
0x2637:012
(P431.12)
Analog input 2: Max torque value
(Analog input 2: Max. torque)
-400.0 ... [100.0] ... 400.0 %
From version 03.00
I/O extensions and control connecons
Congure analog inputs
Analog input 2
262