Address Name / seng range / [default seng] Info
45 Deacvate PID controlling Trigger bit = 1: If PID control is acvated, ignore PID control and drive the
motor in speed-controlled manner.
Trigger bit = 0: If PID control is acvated, drive the motor with PID con-
trol.
Notes:
The PID control can be acvated in 0x4020:001 (P600.01).
4Conguring the process controller ^ 116
46 Set PID output to 0 Trigger bit = 1: If PID control is acvated, I component and the output of
the PID controller are set to 0 and the internal control algorithm is stop-
ped. The PID control remains acve.
Trigger bit = 0: No acon / deacvate funcon again.
4Conguring the process controller ^ 116
47 Inhibit PID I-component Trigger bit = 1: If the PID control is acvated, the I component of the PID
controller is set to 0 and the integraon process is stopped.
Trigger bit = 0: No acon / deacvate funcon again.
4Conguring the process controller ^ 116
48 Acvate PID inuence ramp Trigger bit = 1: the inuence of the process controller is shown by means
of a ramp.
Trigger bit = 0 or not connected: the inuence of the process controller
is shown by means of a ramp.
Notes:
The inuence of the process controller is always acve (not only when
PID control is acvated).
Acceleraon me for showing the inuence of the process controller
can be set in 0x404C:001 (P607.01).
Deceleraon me for hiding the inuence of the process controller
can be set in 0x404C:002 (P607.02).
4Conguring the process controller ^ 116
49 Release holding brake Trigger bit = 1: Release holding brake manually.
Trigger bit = 0: No acon.
Notes:
The manually triggered "Release holding brake" command has a direct
impact on the "Release holding brake [115]" trigger. Thus, the holding
brake can be manually released if the power secon is switched o.
The responsibility for a manual release of the holding brake has the
external trigger source for the "Release holding brake" command.
4Holding brake control ^ 203
50 Select sequence (bit 0) Selecon bits for bit coded selecon of a sequence.
Notes:
The selected sequence is not started automacally.
For a status-controlled start, the funcon "Run/abort sequence [30]"
is available.
4Sequencer control funcons ^ 110
51 Select sequence (bit 1)
52 Select sequence (bit 2)
53 Select sequence (bit 3)
54 Posion counter reset Trigger bit = 1: Reset posion counter manually.
Trigger bit = 0: No acon.
4Posion counter ^ 538
55 Acvate UPS operaon Trigger bit = 1: Acvate UPS operaon.
Trigger bit = 0: No acon / deacvate funcon again.
4EOperaon with UPS ^ 545
0x400E:002
(P505.02)
NetWordIN1 funcon: Bit 1
(NetWordIN1 fct.: NetWordIN1.01)
Seng can only be changed if the inverter is inhibi-
ted.
For further possible sengs, see parameter
0x400E:001 (P505.01). ^ 286
Denion of the funcon that is to be triggered via bit 1 of the mappa-
ble NetWordIN1 data word.
0 Not acve Trigger bit without any funcon.
Conguring the network
Control the inverter via network
Dene your own control word format
289