Address Name / seng range / [default seng] Info
33 Pause sequence (from version 03.00) Trigger bit = 1: Pause sequence.
Trigger bit = 0: Connue sequence.
Notes:
During the pause, the sequence stops in the current step. The expira-
on of the me set for the segment is stopped.
The sequencer setpoint connues to remain acve.
4Sequencer ^ 91
34 Suspend sequence (from version 03.00) Trigger bit = 1: Suspend sequence.
Trigger bit = 0: Connue sequence.
Notes:
This funcon serves to temporarily change over to the standard set-
point or the setpoint source selected via setpoint change-over.
The sequence is connued at the point where it was suspended.
4Sequencer ^ 91
35 Stop sequence (from version 03.00) Trigger bit = 0↗1 (edge): Stop sequence.
Trigger bit = 1↘0 (edge): No acon.
Notes:
If the sequence is stopped, it is jumped to the nal segment.
The further execuon depends on the selected End of sequence
mode0x402F (P824.00).
4Sequencer ^ 91
36 Abort sequence (from version 03.00) Trigger bit = 0↗1 (edge): Abort sequence.
Trigger bit = 1↘0 (edge): No acon.
Notes:
This funcon serves to directly stop the sequence without the nal
segment being executed. In this case, the standard setpoint or the set-
point source selected via setpoint change-over is acve again.
4Sequencer ^ 91
39 Acvate ramp 2 Trigger bit = 1: acvate acceleraon me 2 and deceleraon me 2 man-
ually.
Trigger bit = 0: no acon / deacvate funcon again.
4Ramp mes ^ 84
40 Load parameter set Trigger bit = 0-1 edge: parameter change-over to the value set selected
via "Select parameter set (bit 0)" and "Select parameter set (bit 1)".
Trigger bit = 0: no acon.
Notes:
The acvaon method for the "Parameter change-over" funcon can
be selected in 0x4046 (P755.00).
4Parameter change-over ^ 525
41 Select parameter set (bit 0) Selecon bits for the "Parameter change-over" funcon.
4Parameter change-over ^ 525
42 Select parameter set (bit 1)
43 Acvate fault 1 Trigger bit = 1: Trigger user-dened error 1.
Trigger bit = 0: no acon.
Notes:
Aer the error is triggered, the motor is brought to a standsll with
the quick stop ramp. The inverter is then disabled.
Associated error code:
25249 | 0x62A1 - Network: user fault 1
44 Acvate fault 2 Trigger bit = 1: Trigger user-dened error 2.
Trigger bit = 0: no acon.
Notes:
Aer the error is triggered, the motor is brought to a standsll with
the quick stop ramp. The inverter is then disabled.
Associated error code:
25250 | 0x62A2 - Network: user fault 2
Conguring the network
Control the inverter via network
Dene your own control word format