Address Name / seng range / [default seng] Info
9 Run reverse (CCW) Trigger bit = 0-1 edge: Motor is started in backward rotang direcon
(CCW).
Trigger bit = 1-0 edge: Motor is stopped again.
Notes:
The stop method can be selected in 0x2838:003 (P203.03).
In the case of a bipolar setpoint selecon (e.g ±10 V), the funcon is
executed irrespecve of the rotang direcon. The rotang direcon
is determined by the sign of the setpoint.
The funcon also serves to realise an automac start aer switch-on.
4Starng performance^ 43
The "Reverse rotaonal direcon [13]" funcon can be used in con-
necon with this funcon.
13 Reverse rotaonal direcon Trigger bit = 1: the setpoint specied is inverted (i. e. the sign is inver-
ted).
Trigger bit = 0: no acon / deacvate funcon again.
14 Acvate AI1 setpoint Trigger bit = 1: analog input 1 is used as setpoint source (if the trigger bit
assigned has the highest setpoint priority).
Trigger bit = 0: no acon / deacvate funcon again.
4Analog input 1 ^ 255
15 Acvate AI2 setpoint Trigger bit = 1: analog input 2 is used as setpoint source (if the trigger bit
assigned has the highest setpoint priority).
Trigger bit = 0: no acon / deacvate funcon again.
4Analog input 2 ^ 260
17 Acvate network setpoint Trigger bit = 1: the network is used as setpoint source (if the trigger bit
assigned has the highest setpoint priority).
Trigger bit = 0: no acon / deacvate funcon again.
18 Acvate preset (bit 0) Selecon bits for bit coded selecon and acvaon of a parameterised
setpoint (preset).
4Setpoint presets ^ 87
19 Acvate preset (bit 1)
20 Acvate preset (bit 2)
21 Acvate preset (bit 3)
26 Acvate segment 1 setpoint (from
version 03.00)
Selecon bits for bit coded selecon and acvaon of a parameterised
segment setpoint.
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
4Segment conguraon ^ 93
27 Acvate segment 2 setpoint (from
version 03.00)
28 Acvate segment 3 setpoint (from
version 03.00)
29 Acvate segment 4 setpoint (from
version 03.00)
30 Run/abort sequence (from version 03.00) Trigger bit = 1: Start selected sequence.
Trigger bit = 0: Abort sequence.
Notes:
The assigned trigger bit must remain set to "1" for the duraon of the
sequence.
If the trigger bit is reset to "0", the sequence is aborted. In this case,
the standard setpoint or the setpoint source selected via setpoint
change-over is acve again.
A sequence is selected in a binary-coded fashion via the trigger bits
assigned to the four funcons "Select sequence (bit 0) [50]" ... "Select
sequence (bit 3) [53]".
4Sequencer ^ 91
32 Next sequence step (from version 03.00) Trigger bit = 0↗1 (edge): Next sequence step.
Trigger bit = 1↘0 (edge): No acon.
Notes:
The execuon of the current step is completed even if the me para-
meterised for the segment has not elapsed yet.
The funcon is only relevant for Sequencer mode0x4025 (P800.00) =
"Step operaon [2]" or "Time & step operaon [3]".
A jump to the next sequence step is not possible if the sequence pau-
ses, the sequence is suspended or the nal segment is executed.
4Sequencer ^ 91
Conguring the network
Control the inverter via network
Dene your own control word format
287