EasyManua.ls Logo

Lenze i550

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Name / seng range / [default seng] Info
0x23BA:002
(P580.02)
Modbus TCP stascs: Valid messages received
(MBTCP stascs: Valid Rx messag.)
Read only
From version 04.00
Display of the number of valid messages received.
Aer the maximum value has been reached, the counter starts again
"0".
0x23BA:003
(P580.03)
Modbus TCP stascs: Messages with excepons
(MBTCP stascs: Mess. w. except)
Read only
From version 04.00
Display of the number of messages with excepons that have been
received.
Aer the maximum value has been reached, the counter starts again
"0".
0x23BA:005
(P580.05)
Modbus TCP stascs: Messages sent
(MBTCP stascs: Tx messages)
Read only
From version 04.00
Display of the total number of messages sent.
Aer the maximum value has been reached, the counter starts again
"0".
0x23BE:001
(P585.01)
Modbus TCP/IP diagnoscs of last Rx/Tx data: Receive
oset
(MBTCP Tx/Rx diag: Rx oset)
0 ... [0] ... 240
From version 04.00
For diagnosc purposes, the last received message (max. 16 bytes) is dis-
played in 0x23BE:002 (P585.02). For longer messages, an oset can be
specied here, indicang from which byte of the message the display of
the 16 bytes is to start.
0x23BE:002
(P585.02)
Modbus TCP/IP diagnoscs of last Rx/Tx data: Last Rx
message
(MBTCP Tx/Rx diag: Last Rx message)
Read only
From version 04.00
Display of the message received last.
0x23BE:003
(P585.03)
Modbus TCP/IP diagnoscs of last Rx/Tx data: Trans-
mit oset
(MBTCP Tx/Rx diag: Tx oset)
0 ... [0] ... 240
From version 04.00
For diagnosc purposes, the last sent message (max. 16 bytes) is dis-
played in 0x23BE:004 (P585.04). For longer messages, an oset can be
specied here, indicang from which byte of the message the display of
the 16 bytes is to start.
0x23BE:004
(P585.04)
Modbus TCP/IP diagnoscs of last Rx/Tx data: Last Tx
message
(MBTCP Tx/Rx diag: Last Tx message)
Read only
From version 04.00
Display of the message sent last.
Conguring the network
Modbus TCP
Diagnoscs
443

Table of Contents

Other manuals for Lenze i550

Related product manuals